1. The role of warm ischemia time on functional outcomes after robotic partial nephrectomy: a radionuclide renal scan study from the clock randomized trial.
- Author
-
Antonelli AD, Cindolo L, Sandri M, Veccia A, Annino F, Bertagna F, Di Maida F, Celia A, D'Orta C, De Concilio B, Furlan M, Giommoni V, Ingrosso M, Mari A, Nucciotti R, Olianti C, Porreca A, Primiceri G, Schips L, Sessa F, Bove P, Simeone C, and Minervini A
- Subjects
- Humans, Warm Ischemia, Glomerular Filtration Rate, Treatment Outcome, Nephrectomy, Radionuclide Imaging, Radioisotopes, Retrospective Studies, Robotics, Robotic Surgical Procedures, Kidney Neoplasms surgery
- Abstract
Purpose: To evaluate the relationship between warm ischemia time (WIT) duration and renal function after robot-assisted partial nephrectomy (RAPN)., Methods: The CLOCK trial is a phase 3 randomized controlled trial comparing on- vs off-clamp RAPN. All patients underwent pre- and postoperative renal scintigraphy. Six-month absolute variation of eGFR (AV-GFR), rate of relative variation in eGFR over 25% (RV-GFR > 25), absolute variation of split renal function (SRF) at scintigraphy (AV-SRF). The relationships WIT/outcomes were assessed by correlation graphs and then modeled by uni- and multivariable regression., Results: 324 patients were included (206 on-clamp, 118 off-clamp RAPN). Correlation graphs showed a threshold on WIT equal to 10 min. The differences in outcome measures between cases with WIT < vs ≥ 10 min were: AV-GFR - 3.7 vs - 7.5 ml/min (p < 0.001); AV-SRF - 1% vs - 3.6% (p < 0.001); RV-GFR > 25 9.3% vs 17.8% (p = 0.008). Multivariable models found that AV-GFR was related to WIT ≥ 10 min (regression coefficient [RC] - 0.52, p = 0.019), age (RC - 0.35, p = 0.001) and baseline eGFR (RC - 0.30, p < 0.001); RV-GFR > 25 to WIT ≥ 10 min (odds ratio [OR] 1.11, p = 0.007) and acute kidney injury defined as > 50% increase in serum creatinine (OR 19.7, p = 0.009); AV-SRF to WIT ≥ 10 min (RC - 0.30, p = 0.018), baseline SRF (RC - 0.76, p < 0.001) and RENAL score (RC - 0.60. p = 0.028). The main limitation was that the CLOCK trial was designed on a different endpoint and therefore the present analysis could be underpowered., Conclusions: Up to 10 min WIT had no consequences on functional outcomes. Above the 10-min threshold, a statistically significant, but clinically negligible impact was found., (© 2023. The Author(s).)
- Published
- 2023
- Full Text
- View/download PDF