2. Supply Of Megar, Digital Multi Meter, Loading Cct With Copper Leeds, Variac (auto Transformer), Earth Resistivity Testing Set, Digital Resistance Meter Etc
3. Supply Of Numerical Relay Test Set For Generator Protection, Portable Hv Decade Resistance Box, Portable Hv Ac Test Set, Automatic Capacitance Tan Delta Test Set With Oil Resistivity Test Cell, Portable Karl Fischer Test Set, 3 Phase Portable Transformer
4. Supply Of Transformer Oil Testing Kit (bdv) Transformer Oil Testing Kit (bdv) 1 Kva/0-100 Kv Range Motorized Cum Manual Type (digital) Formeasuring Break Down Voltage /dielectric Strength Of Insulating Oil Used In Transformer/other Switchgears Withc
5. Reconditioning Of 100mva, 220|110kv Cgl Make Power Transformer No-iii Against Achieving Good Idax Test Results (moisture & Oil Conductivity) At 220kv Srs, Kptcl, Hubballi On Partial Turnkey Basis
6. Supply Of Transformer Oil Testing Kit (bdv) 1 Kva|0-100 Kv Range Motorized Cum Manual Type (digital) Formeasuring Break Down Voltage|dielectric Strength Of Insulating Oil Used In Transformer|other Switchgears With Complete Accessories( Test Equipment, Oi
7. Supply Of Numerical Relay Test Set For Generator Protection, Portable Hv Decade Resistance Box, Portable Hv Ac Test Set, Automatic Capacitance Tan Delta Test Set With Oil Resistivity Test Cell, Portable Karl Fischer Test Set, 3 Phase Portable Transformer
8. Supply Of Transformer Insulation Moisture Oil Transformer Insulation Moisture Oil Conductivity Analyzer As Per Specification Attached In 2 Pages(firm Must Upload Technical Data Sheet Along With The Offer For Compliance). Warranty Period: 30 Months
9. Control Transformer Single Phase 50 Hz , Capacity -250va Primary Voltage 440v +|- 5% , Secondary -110 V , Py& Sy Wound With Annealed High Conductivity Copper Wire Duly Insulated For Transformer Rated Viltage In Open Execution Foot Mounted Py&sy Brougt Out
10. Control Transformer Single Phase 50 Hz, Capacity -250va Primary Voltage 440v +|- 5% , Secondary -110 V , Py& Sy Wound With Annealed High Conductivity Copper Wire Duly Insulated For Transformer Rated Voltage In Open Execution Foot Mounted Py&sy Broug
11. Tender For Dga Analysis & Oil Screening Test Of All Icts, Reactors & Transformers Under Hvdc Rs (o&m) Circle, For Fy 2023-24, Dissolved Gas Analysis Is9464-1992, Water Content Is 13567- 1992 Dielectric Dissipation Factor At 90deg, Resistivity At 90deg Is
12. Improvement Of Dielectric Strength Of Transformer Oil By Hot Oil Circulation In Generator Transformer 4r 4y And 4b Phases Uat 4a And Ust 4a During Capital Overhaul 2023 24
13. Improvement Of Dielectric Strength Of Transformer Oil By Hot Oil Circulation In Generator Transformer 4r 4y And 4b Phases Uat 4a And Ust 4a During Capital Overhaul 2023 24
14. Repair Of Various Type T&p For Transmission Line. Repair & Refilling Of Fire Extinguisher. Testing Of Earth Resistivity Of Various Equipment In 132 Kv Substation. Painting Of 40|20 Mva Transformer. Maintenance Of 3 Phase Window Ac
15. Supply Of Portable Relay Secondary Injection Testing Set, Three Phase Test Bench With Phase Shifter, Potential Transformer Test Set, Conductivity Bridge(meas Water Content), Stabilised Dc Power Supply, Cable Fault Location Set, 3 Phase Ckt. Bkr. Timing Me
16. Supply Of Portable Hv Decade Resistance Box, Portable Hv Ac Test Set, Automatic Capacitance Tan-delta Test Set With Oil Resistivity Test Cell, 3-phase Portable Transformer Turns Ratio Vector Group Meter, Portable Primary Secondary Current Injection Test K
17. Supply Of Transformer Insulation Moisture Oil Conductivity Analyzer As Per Specification Attached. Firm Mustupload Technical Data Sheet Compliance
18. Onsite Online Oil Filtration And Further Testing Of Oil Arameters Like Break Down Voltage, Water Content, Dielectric Diss Factor, Resistivity, Neutralization Value, Interfacial Tension, Density For 2 X 10 Mva 33 To 11 Kv Transformer And 1 X 3 Mva 11
19. For Checking|testing Earth Resistivity Of Value For Power Transformer In The Area Of Electricity Urban Distribution Circle,
20. Supply of transformer oil testing kit transformer oil testing kit (bdv), 1 kva|0-100 kv range motorized cum manual type (digital) formeasuring break down voltage|dielectric strength of insulating oil used in transformer|other switchgears withcomplete acc
21. Supply Of Transformer Oil Testing Kit Transformer Oil Testing Kit (bdv), 1 Kva|0-100 Kv Range Motorized Cum Manual Type (digital) Formeasuring Break Down Voltage|dielectric Strength Of Insulating Oil Used In Transformer|other Switchgears Withcomplet
22. Em Iii Replacement Of Oil By New Transformer Oil And Hot Oil Circulation And Its Allied Works Due To The Poor Characteristics Of Transformer Oil Such As Bdv Acidity And Resistivity In Generator Transformer R Phase In Unit V
23. Em Iii Replacement Of Oil By New Transformer Oil And Hot Oil Circulation And Its Allied Works Due To The Poor Characteristics Of Transformer Oil Such As Bdv Acidity And Resistivity In Generator Transformer R Phase In Unit V
24. Provision For Electrical Function Building 70-00002-2480-18 - Pr167634-2480-b
25. Provision For Electrical Function Building 70-00002-2480-18 - Pr167634-2480-b
26. Paper Attached For The Electrical Industry With Characteristics, According To Specifications
27. Complete analytical calculation of static leakage parameters: a step toward HF transformer optimization
28. Diagnosis of EHV and HV transformers through an innovative partial-discharge-based technique
29. The influence of complex permeability on the broadband frequency response of a power transformer
30. Study of transformer resonant overvoltages caused by cable-transformer high-frequency interaction
31. A circular cylindrical, radially polarized ceramic shell piezoelectric transformer
32. Magneto-mechanical resonance in a model 3-phase 3-limb transformer core under sinusoidal and PWM voltage excitation
33. A 1-MV magnetically insulated Tesla transformer
34. Calculation of eddy current field in the ascending flange for the bushings and tank wall of a large power transformer
35. An approach to eliminating dc magnetic flux from the series transformer of a dynamic voltage restorer
36. A practical transformer core loss measurement scheme for high-frequency power converter
37. Millimeter- and submillimeter-wave dielectric measurements of household powders using Fourier transform spectroscopy
38. Modeling dynamic propagation of characteristic gases in power transformers oil-paper insulation
39. Evaluation of breakdown characteristics of oil-immersed transformers under non-standard lightning impulse--insulation characteristics for non-standard lightning impulse waveforms with oscillations
40. A new methodology for the on-wafer characterization of RF integrated transformers
41. Weakly nonlinear behavior of a plate thickness-mode piezoelectric transformer
42. Data mining on a transformer partial discharge data using the self-organizing map
43. Identifying the magnetic part of the equivalent circuit of n-winding transformers
44. Effects of a parallel resistor on electrical characteristics of a piezoelectric transformer in open-circuit transient state
45. Nonlinear processing of the output voltage of a piezoelectric transformer
46. Wavelet-aided SVM tool for impulse fault identification in transformers
47. The study of PD propagation phenomenon in power network
48. Voltage-time and voltage-number characteristics of insulation elements with oil-filled transformers in EHV and UHV classes
49. PD pulse burst characteristics of transformer oils
50. Measurement of three-phase transformer derating and reactive power demand under nonlinear loading conditions