1. ANALYSIS OF THERMAL TRANSFER VALUES IN TEACHING CLASSROOMS
- Author
-
Tri Wulan Sari, Dyah Nurwidyaningrum, Jonathan Saputra, Denny Yatmadi, and Sujito Sujito
- Subjects
green buildings ,sni 03-6389-201 ,wwr ,ottv ,thermal ,Science ,Electrical engineering. Electronics. Nuclear engineering ,TK1-9971 - Abstract
Erratic weather, such as intense heat followed by heavy rain, is causing air pollution in the sky of Jakarta. According to the SNI 03-6389-2011, which deals with energy conservation in building envelopes, the overall thermal transfer value (OTTV) for walls should not exceed 35 W/m2. This study aims to analyze OTTV in Class T and Class S. Class S uses clear glass, while Class T has a shading device in the form of a sunglass sticker. The method used involves calculating the total outer wall area, glass area, window-to-wall ratio (WWR), solar factor value, and then obtaining the OTTV. The results of the study show that the WWR value for Class T was 0.5, while for Class S it was 0.4. The OTTV value in Class T is 58.74 W/m2, whereas the OTTV in Class S is 70.64 W/m2. Despite both classrooms not meeting the SNI requirements, the classrooms using shading devices have OTTV values closer to the SNI standard.
- Published
- 2024
- Full Text
- View/download PDF