1. RADON INHALATION EXPERIMENTS TO TEST RADON EXHALATION KINETICS.
- Author
-
Fojtík, P, Hůlka, J, Bartl, P, Jílek, K, Malátová, I, Kotík, L, Rulík, P, Rubovič, P, and Štekl, I
- Subjects
RADON ,ANALYTICAL mechanics ,FORECASTING ,AIR ,VOLUNTEERS - Abstract
Three experiments were conducted with a volunteer to test the kinetics of the
222 Rn exhalation after a short-time exposure to an elevated222 Rn air concentration. Radon concentration in an exhaled air was measured, complemented by whole body counting of222 Rn decay products in a body. Exhaled activities are compared with the prediction of the recent ICRP biokinetic model for radon. While a rapid equilibration of the exhaled radon activity concentration with that in the air inhaled corresponded with the model, the measured222 Rn exhalation rate was significantly less than modelled. Five hours after termination of the inhalation phase, the radon concentration in the exhaled air decreased to levels expected for non-elevated indoor radon activity concentration. Whole body activities of the222 Rn decay products were found higher than expected. Inhalation of the unattached fraction or residual activity of decay products in the air inhaled may be the explanation. [ABSTRACT FROM AUTHOR]- Published
- 2020