303,032 results
Search Results
2. Used tissue paper as a 3D substrate for non-enzyme glucose sensors.
- Author
-
Zhiyu Chen, Lei Li, Xuanyu Xiao, Yuxin Zhang, Jieyu Zhang, Qing Jiang, Xuefeng Hu, and Yunbing Wang
- Subjects
GLUCOSE analysis ,PAPER recycling ,OXIDATION of glucose ,RECYCLED paper ,DETECTORS ,DENSITY functional theory - Abstract
Non-enzymatic electrochemical blood glucose sensors often suffer from issues such as requiring an alkaline environment, limited monitoring range, and poor anti-interference properties. Carbon substrates have been demonstrated to improve the performance of non-enzymatic sensors, but complex and energy-consuming manufacturing processes restrict their use. Herein, a simple and green approach for the preparation of 3D porous Au/Au-Pt networks (PAAPNs) is proposed using tissue paper for recycling as the nanomaterial substrate to deposit Au-Pt bimetallic nanoparticles. The unique structure of the PAAPNs sensor allows for low-potential operation (-1.0 V) with a wide monitoring range (-0.25 to 36 mM) in a neutral environment. Moreover, the sensor exhibited excellent selectivity (<10% response of interference) even without the use of an anti-interference outer membrane. Further investigation using density functional theory (DFT) simulation revealed the synergistic effect between Au and Pt in promoting glucose oxidation. Overall, this work provides a simple and low-carbon footprint method for creating carbon substrates from tissue paper for recycling, offering new opportunities for fabricating novel value-added nanomaterials for medical sensing applications. [ABSTRACT FROM AUTHOR]
- Published
- 2024
- Full Text
- View/download PDF
3. A paper-based ratiometric fluorescence sensor based on carbon dots modified with Eu3+ for the selective detection of tetracycline in seafood aquaculture water.
- Author
-
Zhang, Jialu, Chen, Yuanyuan, Qi, Ji, Miao, Qinglan, Deng, Dongmei, He, Haibo, Yan, Xiaoxia, and Luo, Liqiang
- Subjects
FLUORESCENCE ,SEAFOOD ,TETRACYCLINE ,TETRACYCLINES ,AQUACULTURE ,DETECTORS - Abstract
Paper-based ratiometric fluorescence sensors are normally prepared using two or more types of fluorescent materials on a paper chip for simple, low-cost and fast detection. However, the choice of multi-step and one-step modifications on the paper chip affects the analytical performance. Herein, a novel paper-based dual-emission ratiometric fluorescence sensor was designed for the selective detection of tetracycline (TC). Carbon dots (CDs) modified with Eu
3+ were combined with a sealed paper-based microfluidic chip by two methods: one-step grafting of CDs-Eu3+ on paper and step-by-step grafting of CDs and Eu3+ on paper. The analytical performance was studied and optimized respectively. The red fluorescence of Eu3+ at 450 nm is enhanced and the blue fluorescence of CDs at 617 nm is quenched by energy transfer in the presence of TC. Under optimal conditions, TC is selectively determined in the linear range from 0.1 μM to 100 μM with a detection limit of 0.03 μM by the step-by-step grafting method. In addition, the sealed paper chip could effectively prevent pollution and volatilization from the reagent. This technique has been used to analyze TC in seafood aquaculture water with satisfactory results. [ABSTRACT FROM AUTHOR]- Published
- 2024
- Full Text
- View/download PDF
4. Office paper and laser printing: a versatile and affordable approach for fabricating paper-based analytical devices with multimodal detection capabilities.
- Author
-
Sousa, Lucas R., Guinati, Barbara G. S., Maciel, Lanaia I. L., Baldo, Thaisa A., Duarte, Lucas C., Takeuchi, Regina M., Faria, Ronaldo C., Vaz, Boniek G., Paixão, Thiago R. L. C., and Coltro, Wendell K. T.
- Subjects
LASER printing ,PRINTMAKING ,PROSTATE-specific antigen ,ELECTROCHEMICAL analysis ,ELECTROSPRAY ionization mass spectrometry ,IRON ,PHOTOVOLTAIC power systems - Abstract
Multiple protocols have been reported to fabricate paper-based analytical devices (PADs). However, some of these techniques must be revised because of the instrumentation required. This paper describes a versatile and globally affordable method to fabricate PADs using office paper as a substrate and a laser printing technique to define hydrophobic barriers on paper surfaces. To demonstrate the feasibility of the alternatives proposed in this study, the fabrication of devices for three types of detection commonly associated with using PADs was demonstrated: colorimetric detection, electrochemical detection, and mass spectrometry associated with a paper-spray ionization (PSI-MS) technique. Besides that, an evaluation of the type of paper used and chemical modifications required on the substrate surface are also presented in this report. Overall, the developed protocol was suitable for using office paper as a substrate, and the laser printing technique as an efficient fabrication method when using this substrate is accessible at a resource-limited point-of-need. Target analytes were used as a proof of concept for these detection techniques. Colorimetric detection was carried out for acetaminophen, iron, nitrate, and nitrite with limits of detection of 0.04 μg, 4.5 mg mL
−1 , 2.7 μmol L−1 , and 6.8 μmol L−1 , respectively. A limit of detection of 0.048 fg mL−1 was obtained for the electrochemical analysis of prostate-specific antigen. Colorimetric and electrochemical devices revealed satisfactory performance when office paper with a grammage of 90 g m−2 was employed. Methyldopa analysis was also carried out using PSI-MS, which showed a good response in the same paper weight and behavior compared to chromatographic paper. [ABSTRACT FROM AUTHOR]- Published
- 2024
- Full Text
- View/download PDF
5. A wash-free, elution-free and low protein adsorption paper-based material for nucleic acid extraction.
- Author
-
Tang, Ruihua, Yan, Xueyan, Li, Min, Du, Aoqi, Yang, Hui, Yin, Huancai, and Xie, Mingyue
- Published
- 2023
- Full Text
- View/download PDF
6. Chitosan-adhered graphene/nano iron tetroxide carbon paper electrode for the detection of hexavalent chromium.
- Author
-
Liangyi Tian, Ting Huang, Yilei Xiang, Yichun Bi, Zihan Yu, Jihuan Xie, Jingping Qiu, Lemin Chen, and Linbin Jiang
- Subjects
CARBON electrodes ,CARBON paper ,HEXAVALENT chromium ,MAGNETITE ,IRON ,GRAPHENE ,CHROMIUM compounds - Abstract
This report presents an investigation into the use of carbon paper electrodes prepared from chitosan-adhered graphene magnetite nanoparticles for the analysis of Cr(VI). The preparation and storage of carbon paper electrodes is a simple process, and these electrodes are easier to replace than electrodes modified by more conventional methods. The electrochemical detection of Cr(VI) using square wave adsorption cathodic dissolution voltammetry (SWAdCSV) with high selectivity and sensitivity, as well as the optimum conditions for the preparation of the electrodes and the electrode parameters affecting the SWAdCSV signal, were the main points of focus of the investigation. Cr(VI) was detected linearly in the range of 4-40 μg L
-1 with a detection limit of 2.84 μg L-1 . The electrode output precision, calculated as %RSD, was 7.16% (n = 6), and this was the measurement used for the detection of Cr(VI) in standard and test samples with recoveries between 89% and 114%. The results were consistent with those obtained using the standard UV-Vis spectrophotometric method with a paired t-test at 95% confidence level. [ABSTRACT FROM AUTHOR]- Published
- 2024
- Full Text
- View/download PDF
7. Rapid fabrication of hydrophobic/hydrophilic patterns on paper substrates for paper spray mass spectrometry.
- Author
-
Arias, Austin, Windham, Peyton E., Cheyne, Natalie A., and Gilliland, William M.
- Subjects
EFAVIRENZ ,MASS spectrometry ,ENERGY dispersive X-ray spectroscopy ,HYDROPHOBIC surfaces ,CONTACT angle ,DETECTION limit ,OXYGEN masks - Abstract
A simple, rapid chemical coating and patterning method was developed and optimized for paper-based substrates for use in paper spray mass spectrometry (PS-MS). A variety of chlorosilanes were explored for coating paper substrates, and their effectiveness in forming hydrophobic surfaces was characterized via contact angle goniometry, scanning electron microscopy, and energy dispersive X-ray spectroscopy. Trichloromethylsilane was selected as the primary coating agent because of the short time required to produce a hydrophobic surface (contact angle > 130°), as well as the ease of patterning. Patterning was performed using 3D-printed masks and an oxygen/plasma cleaner. Optimal mask thickness and oxygen/plasma cleaning parameters were determined to produce channels varying from 0.5 to 2.5 mm in width. The effectiveness of the patterned substrates for PS-MS was determined via analysis of four antiretrovirals: emtricitabine, lamivudine, efavirenz, and dolutegravir. Calibration curves were made for each antiretroviral at varying channel widths, and the limits of detection and limits of quantification for each drug were determined. These results show that this patterning method results in an average 7.2-fold improvement in sensitivity and an average 190-fold improvement in limits of detection over uncoated paper substrates in a neat matrix. In a proof-of-concept experiment, calibration curves were generated for each antiretroviral in urine. A patterned paper substrate with a 2-mm channel resulted in an average 7.4-fold improvement in sensitivity and an average 18-fold improvement in limits of detection over uncoated paper substrates. [ABSTRACT FROM AUTHOR]
- Published
- 2023
- Full Text
- View/download PDF
8. Fluorescence sensor using porous host molecules deposited on filter paper with vapochromic and mechanochromic properties.
- Author
-
Umezane, Sota, Fukutomi, Satoshi, Ono, Toshikazu, Hisaeda, Yoshio, Nishimura, Tomoki, Kawasaki, Riku, and Ikeda, Atsushi
- Subjects
FILTER paper ,FLUORESCENCE ,IRRADIATION ,ABSORBED dose ,MOLECULES ,DETECTORS - Abstract
Naphthalenediimide derivative-absorbed papers, which were prepared by dropping chloroform solution, showed fluorescence under photoirradiation after exposure to vapors of small aromatic guests. The fluorescence intensity and maximum wavelength depended on the type of guest aromatic molecules, similar to the crystal. The naphthalenediimide derivative-absorbed papers showed vapochromic and mechanochromic properties. [ABSTRACT FROM AUTHOR]
- Published
- 2023
- Full Text
- View/download PDF
9. A supramolecular polymer network constructed using a pillararene-based multi-functional monomer and its application as a rewritable fluorescent paper.
- Author
-
Liang, Bicong, Xia, Danyu, Cheng, Yujie, Zheng, Qiang, and Wang, Pi
- Subjects
ELECTRONIC paper ,SUPRAMOLECULAR polymers ,FLUORESCENT polymers ,MONOMERS ,POLYMER networks - Abstract
A simple and mild stimulus-responsive fluorescent supramolecular polymer network was constructed from a pillararene-based multi-functional monomer through multiple noncovalent interactions and used as a rewritable paper. [ABSTRACT FROM AUTHOR]
- Published
- 2023
- Full Text
- View/download PDF
10. On paper characterisation of droplet and evaporation study using impedance spectroscopy.
- Author
-
Siva Prakasam, O. Kare, Basu, Akashlina, Chaudhury, Koel, and Das, Soumen
- Published
- 2024
- Full Text
- View/download PDF
11. Equipment-free determination of ascorbic acid based on the UV-induced oxidation of 3,3′,5,5′-tetramethylbenzidine in a paper-based analysis device.
- Author
-
Liu, Xiaoxia, Hou, Wenya, Zhao, Jinzhong, Zhang, Lili, Li, Anping, and Ma, Ruiyan
- Subjects
VITAMIN C ,ANALYSIS of colors ,OXIDATION ,FILTER paper ,HYDROXYL group ,BLUE - Abstract
A simple, portable and cost-effective paper-based analysis device is developed for quantitative determination of ascorbic acid (AA) based on the UV-induced oxidation of 3,3′,5,5′-tetramethylbenzidine (TMB). The method does not involve the introduction of any enzyme or external oxidants. More importantly, large equipment is not needed and only a 20 μL sample is needed for each analysis which only takes 8 min. The filter paper is pre-treated with TMB and it turns blue upon UV irradiation because TMB is a self-photosensitizer. The phenol hydroxyl groups of AA can inhibit photo-triggered oxidation resulting in a lighter blue color. The color signal is captured using a smartphone and analyzed using color analysis software. A series of factors that affect the performance of the device are investigated, including the concentration of TMB, buffer pH, channel selection, and irradiation time. The analytical performance is evaluated, and the results show that the method has a wide detection range of 0.05–1.0 mmol L
−1 as well as a high selectivity and reproducibility. The proposed method is applied for assaying AA in beverage samples and a VC tablet, and the results correspond to those obtained using the UV method. The results of the recovery test of human serum indicate that the proposed method is feasible in biological samples. This device is easy to fabricate, and convenient to store and transport. It is a truly portable device which has great potential in the on-site assay. [ABSTRACT FROM AUTHOR]- Published
- 2023
- Full Text
- View/download PDF
12. Water-resistant, strong, degradable and recyclable rosin-grafted cellulose composite paper.
- Author
-
Sun, Penghao, Wang, Siheng, Huang, Zhen, Zhang, Lei, Dong, Fuhao, Xu, Xu, and Liu, He
- Subjects
CELLULOSE fibers ,CELLULOSE ,YOUNG'S modulus ,SUSTAINABLE development ,PLASTICS ,DRINKING straws - Abstract
Petroleum-based plastics are useful, but they pose a huge threat to the environment and human health. The development of sustainable cellulose paper materials with excellent mechanical and water-resistance properties to replace plastics is highly desirable but also challenging. Herein, we report a new kind of rosin-based modifier synthesized from fully hydrogenated rosin and (3-glycidoxypropyl)triethoxysilane, which can covalently bind with cellulose fiber networks to improve the hydrophobicity and weaken the capillarity of cellulose paper. The rosin-grafted cellulose composite paper shows a unique combination of water resistance (water absorption of 19.2% and 37.9% in 25 and 90 °C water, respectively) and high strength (tensile strength of 47.9 MPa and Young's modulus of 2.32 GPa). Moreover, the rosin-grafted cellulose composite paper can be completely degraded when buried in soil for up to 100 days, and it can be recycled when treated with an alkali. These impressive performances make rosin-grafted cellulose composite paper a promising eco-friendly alternative material to replace plastics in straws, boxes, cups, bags and so on. [ABSTRACT FROM AUTHOR]
- Published
- 2022
- Full Text
- View/download PDF
13. Rapid and inexpensive process to fabricate paper based microfluidic devices using a cut and heat plastic lamination process.
- Author
-
Kumawat, Nityanand, Soman, Soja Saghar, Vijayavenkataraman, Sanjairaj, and Kumar, Sunil
- Subjects
LAMINATED plastics ,MICROFLUIDIC devices ,MICROFLUIDICS ,POROUS materials ,CHEMICAL industry ,FILTER paper ,CHEMICAL resistance - Abstract
Microfluidic paper-based analytical devices (microPADs) are emerging as simple-to-use, low-cost point-of-care testing platforms. Such devices are mostly fabricated at present by creating hydrophobic barriers using wax or photoresist patterning on porous paper sheets. Even though devices fabricated using these methods are used and tested with a wide variety of analytes, still they pose many serious practical limitations for low-cost automated mass fabrication for their widespread applicability. We present an affordable and simple two-step process – cut and heat (CH-microPADs) – for the selective fabrication of hydrophilic channels and reservoirs on a wide variety of porous media such as tissue/printing/filter paper and cloth types, such as cotton and polyester, by a lamination process. The technique presents many advantages as compared to existing commonly used methods. The devices possess excellent mechanical strength against bending, folding and twisting, making them virtually unbreakable. They are structurally flexible and show good chemical resistance to various solvents, acids and bases, presenting widespread applicability in areas such as clinical diagnostics, biological sensing applications, food processing, and the chemical industry. Fabricated paper media 96 well-plate CH-microPAD configurations were tested for cell culture applications using mice embryonic fibroblasts and detection of proteins and enzymes using ELISA. With a simple two-step process and minimal human intervention, the technique presents a promising step towards mass fabrication of inexpensive disposable diagnostic devices for both resource-limited and developed regions. [ABSTRACT FROM AUTHOR]
- Published
- 2022
- Full Text
- View/download PDF
14. PCB-C4D coupled with paper-based microfluidic sampling for the rapid detection of liquid conductivity.
- Author
-
Yang, Mingpeng, Cao, Mingyi, Zhang, Zhixuan, and Wang, Chaofan
- Published
- 2024
- Full Text
- View/download PDF
15. Paper card-like electrochemical platform as a smart point-of-care device for reagent-free glucose measurement in tears.
- Author
-
Fiore, Luca, Sinha, Ankita, Seddaoui, Narjiss, di Biasio, Jessica, Ricci, Federico, Stojanovic, Goran M., and Arduini, Fabiana
- Subjects
SMART devices ,GLUCOSE ,ELECTRONIC paper ,POLYVINYL chloride ,DETECTION limit ,BLOOD sugar monitors - Abstract
This communication describes the development of polyvinyl chloride electrochemical system in which a paper layer loaded with reagents is inserted into the device, demonstrating a new concept of a paper card-like pad for a reagent-free and easy measurement of the target analyte in solution. This device detects glucose in artificial tears in the range of 0.2–2 mM with a detection limit of 50 μM by simply adding the artificial tears to the paper card-like pad. The novel configuration goes beyond the state of the art, widening the application range of paper in the design of smart analytical devices. [ABSTRACT FROM AUTHOR]
- Published
- 2023
- Full Text
- View/download PDF
16. A dual paper-based nucleic acid extraction method from blood in under ten minutes for point-of-care diagnostics.
- Author
-
Malpartida-Cardenas, Kenny, Baum, Jake, Cunnington, Aubrey, Georgiou, Pantelis, and Rodriguez-Manzano, Jesus
- Subjects
NUCLEIC acid isolation methods ,POINT-of-care testing ,DRUG monitoring ,FILTER paper ,EUKARYOTIC cells - Abstract
Nucleic acid extraction (NAE) plays a crucial role for diagnostic testing procedures. For decades, dried blood spots (DBS) have been used for serology, drug monitoring, and molecular studies. However, extracting nucleic acids from DBS remains a significant challenge, especially when attempting to implement these applications to the point-of-care (POC). To address this issue, we have developed a paper-based NAE method using cellulose filter papers (DBSFP) that operates without the need for electricity (at room temperature). Our method allows for NAE in less than 7 min, and it involves grade 3 filter paper pre-treated with 8% (v/v) igepal surfactant, 1 min washing step with 1× PBS, and 5 min incubation at room temperature in 1× TE buffer. The performance of the methodology was assessed with loop-mediated isothermal amplification (LAMP), targeting the human reference gene beta-actin and the kelch 13 gene from P. falciparum. The developed method was evaluated against FTA cards and magnetic bead-based purification, using time-to-positive (min) for comparative analysis. Furthermore, we optimised our approach to take advantage of the dual functionality of the paper-based extraction, allowing for elution (eluted disk) as well as direct placement of the disk in the LAMP reaction (in situ disk). This flexibility extends to eukaryotic cells, bacterial cells, and viral particles. We successfully validated the method for RNA/DNA detection and demonstrated its compatibility with whole blood stored in anticoagulants. Additionally, we studied the compatibility of DBSFP with colorimetric and lateral flow detection, showcasing its potential for POC applications. Across various tested matrices, targets, and experimental conditions, our results were comparable to those obtained using gold standard methods, highlighting the versatility of our methodology. In summary, this manuscript presents a cost-effective solution for NAE from DBS, enabling molecular testing in virtually any POC setting. When combined with LAMP, our approach provides sample-to-result detection in under 35 minutes. [ABSTRACT FROM AUTHOR]
- Published
- 2023
- Full Text
- View/download PDF
17. Perovskite quantum dots embedded paper photodetectors with high flexibility and self-powered operation.
- Author
-
Guan, Xinwei, Huang, Chien-Yu, Hu, Long, Periyanagounder, Dharmaraj, Lei, Zhihao, Kim, Jiyun, Rahaman, Md. Zahidur, Huang, Jing-Kai, Kumar, Prashant, and Lin, Chun-Ho
- Abstract
Metal halide perovskite quantum dots (QDs) with unique physicochemical properties are promising candidates for next-generation optoelectronics, but they often suffer from stability issues that severely limit their potential for practical applications. In this work, we adopt an oleic acid/oleylamine-free approach to synthesize MAPbBr
3 quantum dot (MQD) papers by incorporating MQDs into cellulose nanofiber frameworks. The abundant long-chain binding ligands containing sulfate terminal groups within the cellulose nanofiber remarkably stabilize the MQD structure, enabling the fabrication of self-power and flexible MQD paper photodetectors with a responsivity of ∼0.19 mA W−1 , detectivity of 1.58 × 108 cm Hz1/2 W−1 , and excellent bendability and reliability after 500 bending cycles. More importantly, these MQD/cellulose-based self-powered photodetectors demonstrate extraordinarily high environmental stability, maintaining more than 90% of the initial responsivity after 60 days. The simple disposability of the paper-based device is also illustrated by burning within one second, suggesting the ease of device elimination. Our work provides a unique approach to designing ultra-stable perovskite QD-based electronics with unprecedented functionalities. [ABSTRACT FROM AUTHOR]- Published
- 2024
- Full Text
- View/download PDF
18. Phytic acid-modified waste paper-derived cellulose for lanthanum capture: fabrication concept and affinity mechanism.
- Author
-
Yuan, Bangwen, An, Qingda, Xiao, Zuoyi, Dong, Xiaoling, Zhu, Kairuo, Shao, Guolin, Zhai, Shangru, and Ha, Chang-Sik
- Subjects
LANGMUIR isotherms ,ADSORPTION kinetics ,WASTE paper ,LANTHANUM ,PHYTIC acid - Abstract
Selective enrichment of La(III) by green material as an industrial raw material is of great research interest. In this study, the selective interaction between P and La(III) was utilized, and waste paper (WP) modified with phytic acid (PA) was used to adsorb La(III) from water using a simple one-pot method. The adsorption capacity was 237.23 mg g
−1 (30 °C, pH = 5, initial concentration of 200 mg L−1 ). The equilibrium isotherm fitted the Langmuir isotherm model well. The adsorption equilibrium was reached after 15 min. The adsorption kinetics followed the pseudo-second-order kinetic model, indicating that the adsorption mechanism of the material towards La(III) is single-layer chemisorption. It selectively adsorbed La(III) from four coexisting substances (Pb, Ni, Cu, and Co). After six cycles, the adsorption efficiency of the adsorbent material remained at 60%. [ABSTRACT FROM AUTHOR]- Published
- 2024
- Full Text
- View/download PDF
19. ZnO nano grafted chitin–chitosan based hybrid composite coated super hydrophobic filter paper for water flow cleaning and oil–water separation applications.
- Author
-
Selvaraj, V., Swarna Karthika, T., Mansiya, C., and Alagar, M.
- Subjects
CHITIN ,HYBRID materials ,FILTER paper ,COMPOSITE coating ,WATER filters ,FOURIER transform infrared spectroscopy - Abstract
A robust superhydrophobic filter paper was developed through a coating technique, simple and facile, cost-effective, eco-friendly, and defensible, for wide portfolio applications. To develop super hydrophobic filter papers, the paper was coated with inorganic–organic hybrid nanocomposites comprising zinc oxide, chitin, and polycaprolactone (chitin–ZnO–PCL) and zinc oxide, chitosan, and polycaprolactone (chitosan–ZnO–PCL) hybrids through the grafting method. The preparation of a superhydrophobic surface by dip-coating deposition is a facile process. Zinc oxide nanoparticles grafted with chitin–PCL and chitosan–PCL hybrids coated on paper exhibit superhydrophobic properties. Water contact angle measurement carried out using a goniometer showed the average static water angle values of 145° and 160° for the chitin–ZnO–PCL and chitosan–ZnO–PCL grafted hybrid coated surfaces, respectively. The surface morphology of the coating was studied using scanning electron microscopy, X-ray powder diffraction, UV radiation, and Fourier transform infrared spectroscopy. In addition, durability, oil/water separation, bio-degradability, and self-cleaning ability through water flush-out were also studied and reported. The results show that the coated filter papers possess excellent superhydrophobic properties for real-time applications. [ABSTRACT FROM AUTHOR]
- Published
- 2023
- Full Text
- View/download PDF
20. Paper-based microfluidics in sweat detection: from design to application.
- Author
-
Ye, Zhichao, Yuan, Yuyang, Zhan, Shaowei, Liu, Wei, Fang, Lu, and Li, Tianyu
- Subjects
MICROFLUIDIC analytical techniques ,MICROFLUIDICS ,EXPERIMENTAL design ,RESEARCH & development - Abstract
Sweat, as a sample that includes a lot of biochemical information, is good for non-invasive monitoring. In recent years, there have been an increasing number of studies on in situ monitoring of sweat. However, there are still some challenges for the continuous analysis of samples. As a hydrophilic, easy-to-process, environmentally friendly, inexpensive and easily accessible material, paper is an ideal substrate material for making in situ sweat analysis microfluidics. This review introduces the development of paper as a sweat analysis microfluidic substrate material, focusing on the advantages of the structural characteristics of paper, trench design and equipment integration applications to expand the design and research ideas for the development of in situ sweat detection technology. [ABSTRACT FROM AUTHOR]
- Published
- 2023
- Full Text
- View/download PDF
21. A paper-based point-of-care device for the detection of cysteine using gold nanoparticles from whole blood.
- Author
-
Kumari, Monika, Kumar, Natish, Kumar, Sunny, Gandhi, Shivani, Zussman, Eyal, and Arun, Ravi Kumar
- Published
- 2024
- Full Text
- View/download PDF
22. Ion imprinted polymers integrated into a multi-functional microfluidic paper-based analytical device for trace cadmium detection in water.
- Author
-
Hu, Jingfang, Wang, Linzhe, Song, Yu, Li, Yansheng, Shen, Yu, Gao, Guowei, Qin, Lei, Wu, Jianfeng, and Mulchandani, Ashok
- Published
- 2024
- Full Text
- View/download PDF
23. Surface-enhanced Raman scattering detection of thiram and ciprofloxacin using chitosan–silver coated paper substrates.
- Author
-
Martins, Natércia C. T., Fateixa, Sara, Nogueira, Helena I. S., and Trindade, Tito
- Subjects
SERS spectroscopy ,CIPROFLOXACIN ,EMERGING contaminants ,WATER quality monitoring ,RAMAN microscopy ,MOLECULAR probes - Abstract
Fast detection of contaminants of emerging concern (CECs) in water resources is of great environmental interest. Ideally, sustainable materials should be used in water quality monitoring technologies implemented for such purposes. In this regard, the application of bio-based materials aimed at the fabrication of analytical platforms has become of great importance. This research merges both endeavors by exploring the application of chitosan-coated paper, decorated with silver nanoparticles (AgNPs), on surface-enhanced Raman scattering (SERS) spectroscopy studies of two distinct types of CECs dissolved in aqueous samples: an antibiotic (ciprofloxacin) and a pesticide (thiram). Our results indicate the superior SERS performance of biocoated substrates compared to their non-coated paper counterparts. The detection limits achieved for thiram and ciprofloxacin using the biocoated substrates were 0.024 ppm and 7.7 ppm, respectively. The efficient detection of both analytes is interpreted in terms of the role of the biopolymer in promoting AgNPs assemblies that result in local regions of enhanced SERS activity. Taking advantage of these observations, we use confocal Raman microscopy to obtain Raman images of the substrates using ciprofloxacin and thiram as molecular probes. We also demonstrate that these biobased substrates can be promising for on-site analysis when used in conjunction with portable Raman instruments. [ABSTRACT FROM AUTHOR]
- Published
- 2024
- Full Text
- View/download PDF
24. Solvent-free strategies for developing latent fingermarks on paper: a review.
- Author
-
Clarke, Kristen T., Cresswell, Sarah L., and Gee, William J.
- Subjects
CRIME laboratories ,FORENSIC chemistry ,HUMAN fingerprints ,SUPPLY chains ,ENVIRONMENTAL forensics - Abstract
With growing environmental concern and supply chain uncertainty, now is a fitting time to re-evaluate solvent-free methodologies in forensic chemistry processes. Here, this paper reviews solvent-free approaches for fingermark visualisation, including chemical fuming and vapour phase treatments, dry-transfer treatments, application of heat, and thermal paper specific treatments. After providing historical context, three objectives have been emphasised: identify feasible scenarios for implementing solvent-free methods; showcase the effectiveness of solvent-free methods relative to their nearest solution-based equivalent; and estimate the technological readiness level of each method discussed. Having reviewed the literature, dry-transfer methods of developing latent fingermarks on paper were found to be the most promising and feasible solvent-free approaches for near-term implementation. Such methods make use of standard materials and equipment commonly found in forensic laboratories, are effective at fingermark visualisation, and mitigate most of the pressing issues pertaining to environmental concern and solvent scarcity. [ABSTRACT FROM AUTHOR]
- Published
- 2023
- Full Text
- View/download PDF
25. High sensitivity and automatic chemiluminescence detection of glucose and lactate using a spin-disc paper-based device.
- Author
-
Tong, Wenqiang, Shi, Jiaming, Yu, Zhihang, Ran, Bin, Chen, Huaying, and Zhu, Yonggang
- Subjects
CHEMILUMINESCENCE ,LACTATES ,ARTIFICIAL saliva ,LACTATION ,GLUCOSE ,SPIN labels ,SIGNAL detection ,CELL culture ,MONOCARBOXYLATE transporters - Abstract
This paper reports a spin-disc paper-based device with 10 individual detection units containing electromagnetic modules controlling the sample incubation time before chemiluminescence (CL) signal detection. After the sample was added to the top paper chip and incubated with the enzyme, the electromagnet was turned off to allow contact between the top and bottom paper. The H
2 O2 generated by the sample flowed vertically to the bottom paper and initiated the oxidase of the luminol to generate the CL signal. After one detection the disc was automatically rotated to the next position to repeat the above detection. The advantage of using the device over the lateral flow and the in situ detection was firstly proved using the detection of H2 O2 and the glucose/lactate sample with 5 minute incubation. The CL intensity was increased 300 times/1000 times as the glucose/lactate was incubated for 5 minutes compared to the non-incubated samples. Afterward, the device was employed to separately detect glucose and lactate diluted in PBS, artificial sweat, artificial saliva, and fresh cell culture media. Finally, the device was employed to detect the glucose and lactate in the media collected over the 24 hour culture of PC3 cells. The uptake and production rates of glucose and lactate were correspondingly determined as 0.328 ± 0.015 pmol h−1 per cell and 1.254 ± 0.053 pmol h−1 per cell, respectively. The reported device has wide application potential due to its capabilities in automatic detection of multiple samples with very high sensitivity and small sample volume (down to 0.5 μL). [ABSTRACT FROM AUTHOR]- Published
- 2024
- Full Text
- View/download PDF
26. Multifunctional droplet handling on surface-charge-graphic-decorated porous papers.
- Author
-
Wu, Jiayao, Fang, Duokui, Zhou, Yifan, Gao, Ge, Zeng, Ji, Zeng, Yubin, and Zheng, Huai
- Subjects
ELECTRIC potential ,SURFACE charges ,HYDROPHOBIC surfaces ,POTENTIAL well ,MICROFLUIDICS - Abstract
Developing a fluidic platform that combines high-throughput with reconfigurability is essential for a wide range of cutting-edge applications, but achieving both capabilities simultaneously remains a significant challenge. Herein, we propose a novel and unique method for droplet manipulation via drawing surface charge graphics on electrode-free papers in a contactless way. We find that opposite charge graphics can be written and retained on the surface layer of porous insulating paper by a controlled charge depositing method. The retained charge graphics result in high-resolution patterning of electrostatic potential wells (EPWs) on the hydrophobic porous surface, allowing for digital and high-throughput droplet handling. Since the charge graphics can be written/projected dynamically and simultaneously in large areas, allowing for on-demand and real-time reconfiguration of EPWs, we are able to develop a charge-graphic fluidic platform with both high reconfigurability and high throughput. The advantages and application potential of the platform have been demonstrated in chemical detection and dynamically controllable fluidic networks. [ABSTRACT FROM AUTHOR]
- Published
- 2024
- Full Text
- View/download PDF
27. An electrochemical molecularly imprinted microfluidic paper-based chip for detection of inflammatory biomarkers IL-6 and PCT.
- Author
-
Wenpeng Li, Jiawen Xiang, Jinglong Han, Mingsan Man, Lingxin Chen, and Bowei Li
- Subjects
IMPRINTED polymers ,INTERLEUKIN-6 ,HOSPITAL utilization ,BIOMARKERS ,DETECTION limit ,ELECTROCHEMILUMINESCENCE - Abstract
Based on surface biomolecular imprinting technology, a rotary microfluidic electrochemical paper-based chip (MIP-ePADs) was proposed for sensitive and selective detection of human interleukin 6 (IL-6) and procalcitonin (PCT). Compared with the traditional method, the sample can be added directly on the MIP-ePAD by rotating the working electrode, which avoids the loss of the liquid to be tested and greatly simplifies the process of electropolymerization imprinting and template elution. Our experimental results show that linear concentration ranges of IL-6 and PCT in the electrochemical molecularly imprinted microfluidic paper-based chip ranged from 0.01 to 5 ng mL
−1 , with their detection limits being 3.5 and 2.1 pg mL−1 , respectively. For the detection of actual serum samples, there was no significant difference between the results of MIP-ePADs and the traditional electrochemiluminescence method used in hospitals, indicating that the paper-based chip can be used for stable and accurate analysis and detection. The chip greatly reduces the cost of clinical trials due to its advantages of easy preparation and low cost. The chip can be used for the analysis of non-antibody inflammation markers and can be widely used in home and hospital treatment detection. This method will not only play an important role in rapid detection, but also provide new ideas for the improvement of rapid detection technology. [ABSTRACT FROM AUTHOR]- Published
- 2023
- Full Text
- View/download PDF
28. 2023 Outstanding Papers published in the Environmental Science journals of the Royal Society of Chemistry.
- Author
-
Cai, Zongwei, Donahue, Neil, Gagnon, Graham, Jones, Kevin C., Manaia, Célia, Sunderland, Elsie, and Vikesland, Peter J.
- Abstract
The document titled "2023 Outstanding Papers published in the Environmental Science journals of the Royal Society of Chemistry" showcases the winners of the Outstanding Paper Awards in environmental science journals. The winners were chosen based on factors like article downloads, Altmetrics, and citations. The document highlights exceptional papers in the field, covering topics such as the removal of PFAS in contaminated soil, the role of sulfuric acid, ammonia, and organics in particle formation over agricultural land, and the association of nanoplastics with human cells. These papers provide valuable insights into environmental concerns and their potential impacts. [Extracted from the article]
- Published
- 2024
- Full Text
- View/download PDF
29. A simple, quick and non-destructive approach for sampling drugs of abuse in tablets and blotter for qualitative analysis by paper spray mass spectrometry.
- Author
-
Diniz, Mariana C. C., de Moura, Fabiana, Machado, Yuri, Coelho Neto, José, and Piccin, Evandro
- Published
- 2023
- Full Text
- View/download PDF
30. Fluorescent filter paper with pH-responsive carbon dots for the on-site detection of biogenic amines in food.
- Author
-
Yan, Jianfeng, Fu, Quanbin, Zhang, Shikai, Shi, Xianbao, Zhang, Yuanhong, Hou, Juying, Duan, Junling, and Ai, Shiyun
- Subjects
BIOGENIC amines ,FILTER paper ,CARBON paper ,FOOD spoilage ,FOOD safety ,DETECTION limit - Abstract
As a kind of organic basic compound containing nitrogen, biogenic amine is released from food spoilage and considered as an indicator for monitoring food freshness. Herein, an excellent dual-emission ratiometric fluorescent sensor for eight kinds of biogenic amines was established via the facile mixing of pH-responsive carbon dots and Rhodamine B. The developed sensor shows a rapid response (10 s), low limit of detection (0.733–3.943 μM) and a wide linear range (0–150 μM). More importantly, a portable fluorescent filter paper was prepared by simple dispersing the filter paper in a solution mixture of carbon dots and Rhodamine B. The obtained fluorescent filter paper based sensor showed an obvious color change in the presence of biogenic amine vapor derived from shrimp and mushroom. The results revealed that this sensor could realize the on-site and visual detection of biogenic amines in real food samples, making it suitable for potential application in food safety monitoring. [ABSTRACT FROM AUTHOR]
- Published
- 2023
- Full Text
- View/download PDF
31. Dual-response fluorescence sensing of H2PO4− and CO32− using AJP filter paper based on a pH-stable CdII-based luminescent metal–organic framework.
- Author
-
Cao, Xiao-Qin, Li, Qiang, Yao, Shu-Li, Zhong, Li-qin, Cao, Lei, Chen, Yong-Qiang, and Liu, Sui-Jun
- Subjects
METAL-organic frameworks ,FILTER paper ,FLUORESCENCE ,LIGHT emitting diodes ,DUAL fluorescence - Abstract
A new Cd
II -based luminescent metal–organic framework (LMOF) with the formula {[Cd(BIBT)(NDC)]·solvents}n (JXUST-32, BIBT = 4,7-bi(1H-imidazol-1-yl)benzo-[2,1,3]thiadiazole and H2 NDC = 2,6-naphthalenedicarboxylic acid) was successfully synthesized by a solvothermal method. JXUST-32 shows a two-dimensional (4,4)-connected network and exhibits significant fluorescence red shift and slight enhancement for H2 PO4 − and CO3 2− sensing with detection limits of 0.11 and 0.12 μM, respectively. In addition, JXUST-32 has good thermal stability, chemical stability and recyclability. Significantly, JXUST-32 represents a fluorescence red-shift dual response MOF sensor for H2 PO4 − and CO3 2− detection and the analytes can be identified by the naked eye, aerosol jet printing filter paper, light-emitting diode beads and luminescent films. [ABSTRACT FROM AUTHOR]- Published
- 2023
- Full Text
- View/download PDF
32. Capacitive platform for real-time wireless monitoring of liquid wicking in a paper strip.
- Author
-
Ruiz-García, Isidoro, Escobedo, Pablo, Ramos-Lorente, Celia E., Erenas, Miguel M., Capitán-Vallvey, Luis F., Carvajal, Miguel A., Palma, Alberto J., and López-Ruiz, Nuria
- Subjects
CAPILLARY flow ,MICROFLUIDICS ,FLOW simulations ,CAPACITANCE measurement ,COMPUTER monitors ,MICROFLUIDIC devices ,POROUS materials - Abstract
Understanding the phenomenon of liquid wicking in porous media is crucial for various applications, including the transportation of fluids in soils, the absorption of liquids in textiles and paper, and the development of new and efficient microfluidic paper-based analytical devices (μPADs). Hence, accurate and real-time monitoring of the liquid wicking process is essential to enable precise flow transport and control in microfluidic devices, thus enhancing their performance and usefulness. However, most existing flow monitoring strategies require external instrumentation, are generally bulky and unsuitable for portable systems. In this work, we present a portable, compact, and cost-effective electronic platform for real-time and wireless flow monitoring of liquid wicking in paper strips. The developed microcontroller-based system enables flow and flow rate monitoring based on the capacitance measurement of a pair of electrodes patterned beneath the paper strip along the liquid path, with an accuracy of 4 fF and a full-scale range of 8 pF. Additionally to the wired transmission of the monitored data to a computer via USB, the liquid wicking process can be followed in real-time via Bluetooth using a custom-developed smartphone application. The performance of the capacitive monitoring platform was evaluated for different aqueous solutions (purified water and 1 M NaCl solution), various paper strip geometries, and several custom-made chemical valves for flow retention (chitosan-, wax-, and sucrose-based barriers). The experimental validation delivered a full-scale relative error of 0.25%, resulting in an absolute capacitance error of ±10 fF. In terms of reproducibility, the maximum uncertainty was below 10 nl s
−1 for flow rate determination in this study. Furthermore, the experimental data was compared and validated with numerical analysis through electrical and flow dynamics simulations in porous media, providing crucial information on the wicking process, its physical parameters, and liquid flow dynamics. [ABSTRACT FROM AUTHOR]- Published
- 2023
- Full Text
- View/download PDF
33. Broadband paper-photodetectors for visible & UV light detection.
- Author
-
Kim, Wonjae, Choi, Minho, and Choi, Jaewu
- Abstract
Hygroscopic cellulose office papers possess the ability to absorb water or moisture, resulting in enhanced electrical conductivity. This study demonstrates the utilization of humidified office papers as versatile, disposable, and renewable broadband photodetectors for diverse applications. The developed paper-photodetectors (P-PDs) allow simultaneous detection of broadband light and temperature. By effectively controlling and managing the water content, sealed office papers offer reliable detection of both visible and UV light, along with temperature measurements. Notably, they are characterized by flexibility, scalability, eco-friendliness, and cost-effectiveness. [ABSTRACT FROM AUTHOR]
- Published
- 2023
- Full Text
- View/download PDF
34. Cell marathon: long-distance cell migration and metastasis-associated gene analysis using a folding paper system.
- Author
-
Huang, Chia-Hao and Lei, Kin Fong
- Subjects
PAPER arts ,CELL migration ,TUMOR suppressor genes ,PROTEIN-tyrosine phosphatase ,PHOSPHOPROTEIN phosphatases ,GENE expression - Abstract
A high mortality rate was found in cancer patients with distant metastasis. Development of targeted drugs for effectively inhibiting cancer metastasis is the key for increasing therapeutic success. In the current study, a folding paper system was developed to mimic a tumor–vascular interface for the study of long-distance cell migration. Correlation between the cell migration distance and metastasis-associated gene was successfully analyzed by disassembling the stacked paper construct. The result revealed that the migration distance and number of migrated cells were highly correlated to cell characteristics. Moreover, immunocytochemistry was directly conducted on the paper layer to study the signaling pathway. Kelch-like and protein tyrosine phosphatase families were examined and the PTPN13 gene was shown to regulate long-distance cell migration. By analyzing the phosphorylated mTOR, the PTPN13 gene was further confirmed to be a tumor suppressor gene that inhibits long-distance cell migration. The folding paper system provides an alternative approach for long-distance cell migration. Metastasis-associated gene expression can be analyzed to potentially develop targeted drugs for cancer metastasis inhibition. [ABSTRACT FROM AUTHOR]
- Published
- 2022
- Full Text
- View/download PDF
35. Microfluidic paper-based analytical device with a preconcentration system for the measurement of anionic surfactants using an optode detector.
- Author
-
Zhu, Shengji and Masadome, Takashi
- Published
- 2024
- Full Text
- View/download PDF
36. Carbon nanotubes modified conductive ink for application to paper-based electrochemical biosensors for pathogenic DNA detection.
- Author
-
Gupta, Niharika, Kumar, D., Das, Asmita, Sood, Seema, and Malhotra, Bansi D.
- Subjects
CONDUCTIVE ink ,CARBON nanotubes ,NUCLEIC acid hybridization ,DNA probes ,NUCLEOTIDE sequence ,POLYSORBATE 80 - Abstract
We report the results of studies relating to the development of a conductive ink-coated, paper-based electrochemical DNA hybridization assay for the detection of the porA pseudogene of Neisseria gonorrhoeae (gonococcal DNA), the causative agent of gonorrhoea. Briefly, a conductive and highly homogenous ink was prepared by dispersing carboxylated MWCNTs (cMWCNTs) in a stable emulsion consisting of terpineol as solvent, carboxymethyl cellulose (CMC) as binder and polysorbate 80 (PS80) as the stabilizing agent. This cMWCNT-based ink was coated onto paper substrates to obtain cMWCNT@paper electrodes with a mean (± standard deviation, SD) resistivity of 1.066 (± 0.33) Ω cm. Furthermore, a magnetic bead (MB)-mediated hybridization assay comprising a specific 5′-biotinylated capture DNA probe (C) and 3′-methylene blue (MetB)-tagged detector DNA probe (D) was designed. These probes hybridized specifically with a porA target DNA sequence (T) forming a sandwich hybridization complex (C-T-D) at the MB surface. Thus formed C-T-D/Av/MB samples with different T concentrations were drop cast and adsorbed onto the cMWCNT@paper for electrochemical detection. The linear detection range and sensitivity of the electrochemical biosensing assay were found to be 100 fM–100 nM and 5.09 μA (log[concentration])
−1 , respectively. The biosensing assay was further shown to detect the target genomic gonococcal DNA in a mixture consisting of different DNA and protein interferents indicating its clinical viability. The results of rheological studies reveal that this thixotropic cMWCNT ink can be utilized for screen printing. These studies demonstrate the utilization of a conductive ink formulation for the fabrication of paper-based electrochemical sensing electrodes having high potential for cost-effective batch production and application in point-of-care (PoC) clinical diagnostics. [ABSTRACT FROM AUTHOR]- Published
- 2023
- Full Text
- View/download PDF
37. Ion-selective membrane modified microfluidic paper-based solution sampling substrates for potentiometric heavy metal detection.
- Author
-
Silva, Rochelle, Zhao, Ke, Ding, Ruiyu, Chan, Wei Ping, Yang, Mingpeng, Yip, Jane Si Qi, and Lisak, Grzegorz
- Subjects
POTENTIOMETRY ,METAL detectors ,DETECTION limit ,HEAVY metals ,UNITS of measurement ,ELECTRODES - Abstract
Paper-based microfluidic solution sampling is a viable option for potentiometric sensors to be used for the determination of analytes in samples with high solid-to-liquid ratios. Unfortunately, heavy metal sensitive electrodes cannot be easily integrated with paper-based solution sampling as heavy metals have strong physicochemical adsorption affinity towards paper substrates. In this work, paper substrates were modified with an ion-selective membrane (ISM) cocktail (used for the preparation of Pb
2+ -ion-selective electrodes (ISEs)) and coupled with model heavy metal Pb2+ -ISEs. It was found that the super-Nernstian response of Pb2+ -ISEs was eliminated when 10 to 50 mg ml−1 of the ISM cocktail was used for the modification of paper substrates. The modification of the paper substrates by Pb2+ -ISM allowed the elimination of adsorption sites. In addition, it resulted in an improvement of sensor performance in terms of their detection limits to be similar to those for conditioned electrodes in standard beaker-based measurements. It is believed that the elimination of super-Nernstian response of the electrodes and improving the potentiometric responses and detection limits of ISEs were attributed to the compatibility improvement of the paper substrates and Pb2+ -ISEs to the same type of ISM. [ABSTRACT FROM AUTHOR]- Published
- 2022
- Full Text
- View/download PDF
38. Preparation of coated paper reinforced by a blend of anionic-starch-based nanocellulose/chitosan and its properties.
- Author
-
Xue, Meigui, Wen, Zhou, Huang, Ruquan, Chai, Xinsheng, Li, Wei, Chen, Chunxia, and Chen, Hongqian
- Published
- 2022
- Full Text
- View/download PDF
39. Nanoscale pores introduced into paper via mesoporous silica coatings using sol–gel chemistry.
- Author
-
Mikolei, J. J., Richter, D., Pardehkhorram, R., Helbrecht, C., Schabel, S., Meckel, T., Biesalski, M., Ceolin, M., and Andrieu-Brunsen, A.
- Published
- 2023
- Full Text
- View/download PDF
40. Detection of azadirachtin from neem kernels using a paper-based sandwich sensor.
- Author
-
Sinu, Kurian, Savitha, Rangasamy, Ranjit, Bauri, and Pushpavanam, Subramaniam
- Published
- 2024
- Full Text
- View/download PDF
41. Paper-based ratiometric fluorescent sensing platform based on mixed quantum dots for the detection of glucose in urine.
- Author
-
Song, Keke, Liu, Chenying, Chen, Guangbin, Zhao, Wenhao, Tian, Shufang, and Zhou, Qian
- Published
- 2024
- Full Text
- View/download PDF
42. Direct analysis of tree rings using laser ablation-ICP-MS and quantitative evaluation of Zn and Cu using filter paper as a solid support for calibration.
- Author
-
Moreau, Pedro dos Santos and Arruda, Marco Aurélio Zezzi
- Subjects
DENDROCHRONOLOGY ,RING lasers ,INDUCTIVELY coupled plasma mass spectrometry ,FILTER paper ,TREE-rings - Abstract
This work demonstrated a quantitative determination of Cu and Zn in tree rings using laser ablation-ICP-MS and the use of quantitative filter paper as a solid support for constructing the calibration curve using aqueous standards. After cleaning the filter paper using 10% v/v HNO
3 for 30 min and drying it, 4 μL of standards is delivered on the filter surface and the results are attained with no normalized data. The analytical curves ranged from 0.5 to 10.0 μg g−1 and 5.0 to 100.0 μg g−1 for Cu and Zn, respectively, and the accuracy of the results was checked not only through Certified Reference Materials (NIST 1573a, tomato leaves and 1575a, pine needles) but also using ICP-MS (Inductively Coupled Plasma Mass Spectrometry) as a reference technique. Then, using such minimalist strategies, this method was applied for evaluating the mass fractions of Zn and Cu directly in tree rings. Three parallel ablation lines were drawn with a 220 μm distance between each one, with the same size of the tree ring samples. The average mass fractions for each tree ring and between the 3 ablated lines were at most ca. 18 and 13 μg g−1 for Cu and Zn, respectively, in Hymenaea courbaril, ca. 4 and 9 μg g−1 for Cu and Zn, respectively, in Tipuana tipu, and ca. 160 μg g−1 and- Published
- 2022
- Full Text
- View/download PDF
43. Printable biosensors towards next-generation point-of-care testing: paper substrate as an example.
- Author
-
Liu, Yaolin, Lu, Sheng, Zhang, Zhiheng, Yang, Zhugen, Cui, Xiaolin, and Liu, Guozhen
- Subjects
BIOSENSORS ,POINT-of-care testing ,LASER printing ,SCREEN process printing ,ENVIRONMENTAL monitoring ,INK ,ELECTROCHEMICAL sensors - Abstract
Printable biosensors have gained numerous exciting advancements towards downstream applications in fundamental biomedical research, healthcare, food safety, environmental monitoring and governance, and to name a few. Particularly, paper-based printable biosensors have gained rising popularity in providing affordable platforms due to their merits, such as cost-effective, accurate, simple, and efficient detection of diseases for clinical diagnosis. In addition to advantages and opportunities in point-of-care detection, printable biosensors are also facing challenges. Herein, this review aims to provide a systematic summary of the development of printable biosensors, with a special focus on paper-based printable biosensors. Different types of substrates for printable biosensors are highlighted with a focus on paper substrates which have superior properties like low-cost, simple, flexible, lightweight, recyclable, etc. In addition, current printing technologies to fabricate paper-based sensors, including wax printing, photolithography, screen printing, inkjet printing, and laser printing summarize, are discussed, together with strategies for biomolecular fabrication on substrates and transducers. Finally, we also discuss the challenges and possible future perspectives, hoping to provide researchers and clinicians with informative insights into paper-based printable biosensors for smart and effective point-of-care detection. [ABSTRACT FROM AUTHOR]
- Published
- 2023
- Full Text
- View/download PDF
44. A closed-loop and sustainable approach for the fabrication of plastic-free oil- and water-resistant paper products.
- Author
-
Li, Zhao, Rabnawaz, Muhammad, Sarwar, Mohammed G., Khan, Burhan, Krishna Nair, Aditya, Sirinakbumrung, Nopphachai, and Kamdem, Donatien Pascal
- Subjects
PAPER products ,KRAFT paper ,PAPER pulp ,MARINE pollution ,GRAFT copolymers ,SURFACE energy ,BIODEGRADABLE plastics - Abstract
The current open-loop practices employed to render paper substrates water- and oil-repellent for packaging and non-packaging applications have generated ocean pollution and have placed daunting burdens on landfills. In this study, we report a green, unique and facile approach for the fabrication of grease- and water-resistant paper products with 100% recyclability of the paper pulp. Low surface energy polydimethylsiloxane (PDMS) was grafted onto a biobased chitosan polymer via urea linkages to prepare the graft copolymer chitosan-graft-polydimethylsiloxane (chitosan-g-PDMS). Chitosan-g-PDMS was then applied as a coating onto an unbleached Kraft paper substrate from an aqueous solution. The coated paper substrates exhibited good hydrophobic properties with a water contact angle of 120.53 ± 0.96° and a Cobb 60 value of 9.89 ± 0.32 g m
−2 . The coated paper substrates also showed good oil-resistance as evident from the kit rating value of 11.7/12. The tensile strength, crushing resistance, bending stiffness, and internal tearing resistance of the paper before and after coating treatment was determined. Scanning electron microscopy (SEM) analysis was used to characterize changes in the porosity of the paper before and after the coating. The pulp recyclability of the coated paper was validated by subjecting the coated paper samples to repulping and washing treatment. This novel and practical approach can provide significant environmental benefits by offering plastic-free, fluorine-free and fully-recyclable water- and grease-resistant paper; thus promoting sustainability due to its unique closed-loop nature. [ABSTRACT FROM AUTHOR]- Published
- 2019
- Full Text
- View/download PDF
45. A paper-based dual functional biosensor for safe and user-friendly point-of-care urine analysis.
- Author
-
Yujia Li, Yingqi Kong, Yubing Hu, Yixuan Li, Asrosa, Rica, Wenyu Zhang, Boruah, Buddha Deka, Yetisen, Ali K., Davenport, Andrew, Tung-Chun Lee, and Bing Li
- Subjects
URINALYSIS ,BIOSENSORS ,PRUSSIAN blue ,GLUCOSE analysis ,GLUCOSE oxidase ,GRAPHITE composites ,ORGANOPHOSPHORUS pesticides - Abstract
Safe, accurate, and reliable analysis of urinary biomarkers is clinically important for early detection and monitoring of the progression of chronic kidney disease (CKD), as it has become one of the world's most prevalent non-communicable diseases. However, current technologies for measuring urinary biomarkers are either time-consuming and limited to well-equipped hospitals or lack the necessary sensitivity for quantitative analysis and post a health risk to frontline practitioners. Here we report a robust paper-based dual functional biosensor, which is integrated with the clinical urine sampling vial, for the simultaneous and quantitative analysis of pH and glucose in urine. The pH sensor was fabricated by electrochemically depositing IrOx onto a paper substrate using optimised parameters, which enabled an ultrahigh sensitivity of 71.58 mV pH
-1 . Glucose oxidase (GOx) was used in combination with an electrochemically deposited Prussian blue layer for the detection of glucose, and its performance was enhanced by gold nanoparticles (AuNPs), chitosan, and graphite composites, achieving a sensitivity of 1.5 μA mM-1 . This dual function biosensor was validated using clinical urine samples, where a correlation coefficient of 0.96 for pH and 0.98 for glucose detection was achieved with commercial methods as references. More importantly, the urine sampling vial was kept sealed throughout the sample-to-result process, which minimised the health risk to frontline practitioners and simplified the diagnostic procedures. This diagnostic platform, therefore, holds high promise as a rapid, accurate, safe, and user-friendly point-of-care (POC) technology for the analysis of urinary biomarkers in frontline clinical settings. [ABSTRACT FROM AUTHOR]- Published
- 2024
- Full Text
- View/download PDF
46. A novel ratiometric design of microfluidic paper-based analytical device for the simultaneous detection of Cu2+ and Fe3+ in drinking water using a fluorescent MOF@tetracycline nanocomposite.
- Author
-
Al-Jaf, Sabah H., Mohammed Ameen, Sameera Sh., and Omer, Khalid M.
- Subjects
WATER use ,POLLUTANTS ,NANOCOMPOSITE materials ,WATER quality ,WATER sampling - Abstract
The regular and on-site monitoring of ions in drinking water is essential for safeguarding public health, ensuring high water quality, and preserving the ecological balance of aquatic ecosystems. Thus, developing a portable analytical device for the rapid, cost-effective, and visual on-site detection of multiple environmental pollutants is notably significant. In the present work, a novel ratiometric microfluidic paperbased analytical device (µPAD) was designed and developed for the simultaneous detection of Fe3+ and Cu2+ ions in water samples taking advantages from built-in masking zone. The µPAD was functionalized with a greenish-yellow fluorescent Zn-based metal-organic framework@tetracycline (FMOF-5@TC) nanocomposite, and the ratiometric design was based on the change in emission color from greenish yellow (FMOF-5@TC) to blue (FMOF-5). The µPAD consisted of one sample zone linked to two detection zones via two channels: the first channel was for the detection of both ions, while the second was intended for detecting only Cu2+ ions and comprised a built-in masking zone to remove Fe3+ ions prior to reaching the detection zone. The corresponding color changes were recorded with the aid of a smartphone and RGB calculations. The linear ranges were 0.1-80 µM for Cu2+ and 0.2-160 µM for Fe3+, with limits of detection of 0.027 and 0.019 µM, respectively. The simple µPAD design enabled the simultaneous detection of Cu2+ and Fe3+ ions in drinking water samples with excellent accuracy and precision, with spike recoveries of 81.28-96.36% and 83.01-102.33% for Cu2+ and Fe3+, respectively. [ABSTRACT FROM AUTHOR]
- Published
- 2024
- Full Text
- View/download PDF
47. Smartphone-based paper strip assay for putrescine and spermidine detection using hybrid organic–inorganic perovskite with Eu3+ complex.
- Author
-
Truong, Thi Thuy, Huy, Bui The, Huong, Le Thi Cam, Truong, Hai Bang, and Lee, Yong-Ill
- Subjects
SPERMIDINE ,PUTRESCINE ,PEROVSKITE ,SMARTPHONES ,FLUORESCENCE quenching ,FLUORESCENT probes ,POLYAMINES ,BIOGENIC amines - Abstract
A new method utilizing fluorescent ratiometry is proposed for detecting putrescine and spermidine. The method involves the use of a fluorescent probe comprising a 2D halide perovskite synthesized from octadecylamine-iodine and PbI
2 via a grinding-sonicating technique, along with a Eu3+ -complex. Upon excitation at 290 nm, the probe fluoresces at two distinguishable wavelengths. The addition of putrescine and spermidine significantly decreases the emission of the 2D halide perovskite at 496 nm, while the emission of the Eu3+ -complex at 618 nm remains stable. The color changes of the probe depend on the concentration of putrescine and spermidine, and the assay offers linearity over a wide concentration range (30–4000 ng mL−1 ), a low detection limit (4 ng mL−1 for putrescine, and 7 ng mL−1 for spermidine), and a quick response time. Furthermore, a portable device based on a smartphone can be used to record the color change of the paper test strip using the prepared fluorescent materials. The fluorescence quenching mechanism of the probe is explained as dynamic quenching. [ABSTRACT FROM AUTHOR]- Published
- 2024
- Full Text
- View/download PDF
48. An innovative transportable immune device for the recognition of α-synuclein using KCC-1-nPr-CS2 modified silver nano-ink: integration of pen-on-paper technology with biosensing toward early-stage diagnosis of Parkinson's disease.
- Author
-
Saadati, Arezoo, Baghban, Hossein Navay, Hasanzadeh, Mohammad, and Shadjou, Nasrin
- Published
- 2024
- Full Text
- View/download PDF
49. Paper-based colorimetric sensors for point-of-care testing.
- Author
-
Ko, Anthony and Liao, Caizhi
- Published
- 2023
- Full Text
- View/download PDF
50. 2023 Outstanding Papers published in the Environmental Science journals of the Royal Society of Chemistry.
- Author
-
Zongwei Cai, Donahue, Neil, Gagnon, Graham, Jones, Kevin C., Manaia, Célia, Sunderland, Elsie, and Vikesland, Peter J.
- Published
- 2024
- Full Text
- View/download PDF
Discovery Service for Jio Institute Digital Library
For full access to our library's resources, please sign in.