1. A novel Q‐value‐based nomogram for single intracorneal ring segment implantation versus standard manufacturer's nomogram combined with accelerated cross‐linking for treatment of keratoconus: a randomized controlled trial.
- Author
-
Iqbal, Mohammed, Elmassry, Ahmed, Mounir, Amr, Ibrahim, Ola, and Soliman, Ashraf
- Subjects
- *
RANDOMIZED controlled trials , *NOMOGRAPHY (Mathematics) , *KERATOCONUS , *VISUAL acuity , *CORNEA - Abstract
Purpose: To compare the efficacy of implanting a single Keraring segment according to a novel Q‐value‐based nomogram (QN) to that of segment implantation according to the manufacturer's standard nomogram (SN), for keratoconus treatment. Methods: This was a prospective, randomized controlled trial of 104 patients (104 eyes) with Amsler‐Krumeich grade 1 or 2 keratoconus, and type 1 or 2 cone asymmetry determined according to manufacturer's classification. They were randomly distributed into two groups: group A patients (n = 52) underwent Keraring implantation according to the SN, and group B patients (n = 52) underwent implantation of a single (210° arc‐length) Keraring segment according to the QN. Both treatments were combined with accelerated transepithelial cross‐linking, and follow‐up was 6 months. Main outcome measures were preoperative and postoperative visual acuity, subjective refraction and corneal topography. Results: At postoperative month 6, group B exhibited statistically significantly higher values of mean uncorrected distance visual acuity (UDVA), sphere, K2, K‐average, K‐max and Q‐anterior (p = 0.02, 0.01, 0.002, 0.001, 0.0001 and 0.03, respectively) compared to that of group A. However, group A exhibited better refractive cylindrical improvements (p = 0.04). In group A, we documented spontaneous extrusion of one Keraring segment. Conclusion: Single 210° arc‐length segment implantation using our objective QN was more efficacious for keratoconus treatment than using the subjective SN. The nomograms were comparable when the Q‐anterior value was >−1.00; however, the QN was superior to the SN when the Q‐anterior value was ≤−1.00. The QN yielded greater postoperative UDVA and smoother corneal remodelling than did the SN for treatment of grade 1 and 2 keratoconic eyes. [ABSTRACT FROM AUTHOR]
- Published
- 2021
- Full Text
- View/download PDF