3 results on '"Dash, Om Prakash"'
Search Results
2. Design and characteristics of a novel single-plane Compton gamma camera based on GAGG scintillators readout by SiPMs.
- Author
-
Dash, Om Prakash, Bokulić, Tomislav, Bosnar, Damir, Žugec, Petar, and Makek, Mihael
- Subjects
- *
COMPTON imaging , *SCINTILLATION cameras , *SCINTILLATORS , *GAMMA ray sources , *PHOTOMULTIPLIERS , *REAR-screen projection - Abstract
We designed a novel, compact, single-plane Compton gamma camera based on GAGG:Ce scintillators read out by silicon photomultipliers. The Compton gamma camera comprises the scatterer and the absorber layers consisting of 8x8 arrays of 3 mm × 3 mm × 3 mm GAGG:Ce pixels. The individual pixels in the scatterer layer are optically coupled to the corresponding pixels in the absorber by the matching 3 mm × 3 mm × 20 mm plexiglass lightguides, and hence both the scatterer and the absorber pixel in one column are readout by the same SiPM. We present the first results of the measured characteristics of the detector. The average energy resolution at 662 keV of the front and the back GAGG:Ce layer is found to be 8.9% ± 1.9% and 10.8% ± 1.6%, respectively. The Compton events are reconstructed based on kinematic conditions and detector geometry and the first image of a 662 keV gamma source is reconstructed using a simple back projection algorithm. [ABSTRACT FROM AUTHOR]
- Published
- 2023
- Full Text
- View/download PDF
3. COMPARISON OF FACTORS AFFECTING DEPRESSION IN PATIENTS ON HEMODIALYSIS AND CONTINUOUS AMBULATORY PERITONEAL DIALYSIS.
- Author
-
Upadhyaya, Bal Krishna, Khaira, Ambar, Khatri, Priyanka, Mahajan, Sandeep N., Rathi, Deepa Dash Om Prakash, Tiwari, Suresh C., and Kumar, Guresh
- Subjects
- *
PERITONEAL dialysis , *HEMODIALYSIS , *CONTINUOUS ambulatory peritoneal dialysis , *HEMOGLOBINS , *QUALITY of life , *SOCIAL status , *MENTAL depression - Abstract
Aim: To see prevalence of depression in patients on hemodialysis and continuous ambulatory peritoneal dialysis. To assess and compare factors responsible for depression in these patients. Materials and Methods: 52 patients on continuous ambulatory peritoneal dialysis (CAPD), and 130 patients on hemodialysis (HD) were enrolled for the study. All the patients were administered becks depression inventory (BDI), a self-assessment questionnaire and cognitive depression inventory (CDI) was calculated. They were also assessed for quality of life (QOL) on a 1-5 self-reported Likert scale. Clinical and biochemical characteristics affecting depression in patients on both modalities of renal replacement therapy were evaluated and compared. Results: The mean age of patients on CAPD and HD was 60.1±8.7 and 39.69±14.6 years respectively (P- 0.001) with a male / female ratio of 63.4% and 65.3% (P- 0.86) respectively. There was a significant difference in the mean hemoglobin (9.69±1.65 vs 8.08±1.96 g/dl, P- 0.001) and serum albumin levels (3.21±0.65 gm/dl vs 3.6±0.80 gm/dl, P- 0.003) in patients of CAPD and HD. Overall more patients on CAPD 42/52 were depressed when compared to patients on HD 56/130 (P- 0.0001). Overall 19.2% patients on HD had mild depression, 14.6% had moderate depression and 7.6% had severe depression compared to 34.6%, 26.9% and 19.2% in patients on CAPD. Higher BDI scores, lower QOL scores and greater no of episodes of peritonitis were seen in patients on CAPD, who had a serum albumin < 3.5 gm/dl (P- 0.001, 0.04, 0.01). Depression in patients on CAPD was associated with hemoglobin < 10 g/dl but not with socio-economic status, occupation and duration of CAPD. Poor quality of life in patients on CAPD was associated with serum albumin level <3.5/dl, mean hemoglobin levels < 10 g/dl but not with socio-economic status, occupation and duration of CAPD. Episodes of peritonitis were more frequent in patients, who were depressed and had a lower mean serum albumin. BDI scores in CAPD patients correlated inversely with serum albumin (r- -0.595, P < 0.0001), hemoglobin (r- -0.493, P-< 0.0001) and quality of life (r- -0.803, P- < 0.0001) whereas quality of life correlated inversely with serum albumin (r- -0.803, P < 0.001) and hemoglobin (r- -0.412, P-0.002). Patients on HD with mean hemoglobin < 10g/dl (n-96) had higher mean BDI scores 14.70±11.0 and CDI scores 9.69±6.9 and poor QOL scores 2.88±1.23 when compared to patients with a mean hemoglobin > 10g/dl, BDI- 10.44±7.29, CDI-6.94±5.48 and QOL-3.5±1.16 (P- 0.003, 0.04, 0.01) respectively. Depression in patients on HD was unrelated to duration of illness, employment, and education and serum albumin levels. Undepressed patients on HD had significantly better quality of life when compared to depressed patients (P- < 0.002). They also had better hemoglobin levels when compared to severely depressed patients (P- 0.02). BDI scores correlated inversely with quality of life (r- -0.62, P- <0.0001) and hemoglobin levels (r- -0.213, P- 0.01), however there was no correlation with mean albumin, education levels, socio-economic status or duration of illness. Conclusion: Patients of CAPD are more depressed than patients on HD. In patients on CAPD, the depression and poor quality of life correlates with poor serum albumin and lower hemoglobin levels. In patients on HD, depression leads to a poor quality of life and correlates with poor hemoglobin levels. Attempts should be made to correct these reversible factors in this population of patients. [ABSTRACT FROM AUTHOR]
- Published
- 2007