1. Safety Analysis of the 70 kA ITER HTS Current Lead Demonstrator.
- Author
-
Helter, R.
- Subjects
HIGH temperature superconductors ,ELECTRIC currents ,SHUNT electric reactors ,HELIUM ,NUCLEAR fusion - Abstract
For the superconducting magnet system of the International Thermonuclear Experimental Reactor, ITER, 60 current leads for a total current of more than 2500 kA are needed. The use of High Temperature Superconductor current leads (HTS-CL) will reduce the resultant large refrigerator load considerably. Within the EU Fusion Technology Programme, the Forschungszentrum Karlsruhe and CRPP have developed and built a 70 kA HTS-CL demonstrator optimized for 50 K Helium operation. In 2004-2005, the CL was successfully tested with 50 K as well as 80 K Helium, and finally with LN2. In the meantime, ITER has decided to use HTS-CLs for the magnet system and China has taken the responsibility to provide the sc feeders for ITER including the current leads. In this paper, the performance of a 70 kA HTS-CL in fault conditions will be analysed using the FZK-CRPP demonstrator as a model. In particular, the quench performance and the safety behavior in case of a loss-of-flow accident (LOFA) will be described and an extrapolation of the leads performance in real ITER conditions will be given. Finally the effect of different shunt materials is discussed. [ABSTRACT FROM AUTHOR]
- Published
- 2009
- Full Text
- View/download PDF